NaviNet
NaviNet ESP/E2K

General Description
-
Convert analogue sensors to NMEA2000/
-
The MFD ECP/E2K devices enables displaying Engine data on any mobile device (smartphone, tablet, or laptop).
-
Supports Engine RPM. Temperature, oil pressure. fuel tanks ,Fuel consumption ,Engine hours.
-
Setting Sensors offset in order to adjust to any engine type.
-
Control and display are available via a web application, allowing multiple mobile devices to view data simultaneously.
Split-screen viewing is supported. -
ECP-1 for 1 engine with 4 analog sensors. (List price 99$)
-
ECP-2 for 2 engines with 8 analog sensors. (List price 120$)
-
E2K-1 for 1 engine with 4 analog sensors. + NMEA2000. (List price 160$)
-
E2K-2 for 2 engine with 8 analog sensors. + NMEA2000 (Engine 1 can use for Generator , (List price 180$)
-
OTA firmware update over Wi-Fi.
N-E2K-1 & N-E2K-2
In addition to display on any mobile device it connecting to NMEA2000 enabling
To see engine data at any N2K MFD devices that supporting engine display., like Raymarin AXIOM.
Sending The following NMEA2000 PGN
PGN 127488 — Engine Parameters, Rapid Update
PGN 127489 — Engine Parameters, Dynamic
PGN 127497 — Trip Parameters, Engine
PGN 60928 — ISO Address
PGN 59904 — ISO Request
PGN 126996 — Product Information
PGN 126998 — Configuration Information
PGN 129026 — COG & SOG, Rapid Update
PGN 127250 — Vessel Heading
PGN 127505- _Fuel
Advanced calibrations
Usually not required since defaulted are manufactory calibrated.
-
Setting Sensors offset in order to adjust any engine type.
-
Temp offset is added in °C/F after conversion.
-
Slope offset multiply (Vadc + Offset) for Fuel/Oil only
-
Fuel Slope: Fuel slope multiplier
-
Oil Slope: Oil slope multiplier
-
Fuel & oil calculations use selected US / EU standard.
-
Fuel offset (V): Fuel sensor voltage offset (VDO legacy voltage path).
-
Oil offset (V): Oil sensor voltage offset (legacy voltage path).
-
Temp offset Not adjusted . use auto interpolation calibration.
-
rpm offset (RPM): Legacy RPM offset (if used in your chain).
-
Fuel Slope: Fuel slope multiplier
-
Oil Slope: Oil slope multiplier
-
fuel Lph (L/h): Manual fuel consumption.
-
hours Base (hours): Engine hours base value.
-
: Standard selector (EU/US) .
-
oil Mode: 'volt 'VDO or 'ohm'.
-
oilR0, oil Rmax (Ω) & oil Max Bar/PSI: Ohm sender parameters.
-
: RPM linear calibration.
-
rpm Preset: UI preset for RPM profile., Enable to change Gauge color limits,
-
idle Rpm, cruise Rpm, yellow Rpm, red Rpm, max Rpm: Gauge z